Scroll Back to Top

MSH6 Gene Sequencing (Known Mutation)

CPT 81299
Synonyms
  • Lynch Syndrome

Test Details

Cancer Type

Colorectal cancer (CRC), Endometrial, Hereditary cancer, Lynch syndrome

Technology Used

Molecular

Turnaround Time

23 - 28 days

Use

Identify who in a family harbors the familial mutation and is at high risk of the disease and who does not harbor the familial mutation and is not at increased risk of the disease. Family testing for known familial mutations can identify presymptomatic mutation carriers within affected families who are at high risk of developing the familial disease.

Special Instructions

This option is available when the mutation is known and can be documented by the ordering physician. If the mutation cannot be documented, please order test 511636.

Test orders must include an attestation that the provider has the patient's informed consent for genetic testing. See sample physician office consent form: Consent for Genetic Testing. In the case of family tests (ie, known mutations), please submit the result report of the first patient tested in the family (the index case), if not performed at a LabCorp facility. Other family members are subsequently tested for the specific mutation found in the first patient tested.

Limitations

Selected regions of the coding sequence of MSH6 are amplified by polymerase chain reaction and each PCR product amplicon) then sequenced bi-directionally, using Sanger sequencing. Nucleotide and codon number are based on the mRNA isoform NM_000179 for the MSH6 gene.

Sequencing cannot detect variants in regions not covered by this analysis, including noncoding or deep intronic variants and may not reliably detect changes in repetitive elements, such as microsatellite repeats. Sequencing may not detect mosaic variants, inversions, or other genomic rearrangements such as transposable element insertions. Sequence analysis may also be affected by allele drop-out due to the presence of a rare variant under a primer site or homopolymeric regions. The method does not allow any conclusion as to whether two heterozygous variants are present on the same or on different chromosome copies.

This test is not intended to detect somatic variants. Bone marrow transplantation may affect the outcome of these results. Please contact LabCorp to discuss testing options at 1-800-345-GENE.

This test was developed, and its performance characteristics determined, by LabCorp. It has not been cleared or approved by the US Food and Drug Administration (FDA).

Methodology

DNA sequencing

Specimen Requirements

Information on collection, storage, and volume

Specimen

Whole blood; DNA is accepted (Call 800-345-4363 for DNA collection information.)

Volume

2 mL

Container

Lavender-top (EDTA) tube

Storage Instructions

Maintain specimen at room temperature.

Causes for Rejection

Container broken or leaking; container not labeled or label not legible; improper anticoagulant

Collection

Samples may be stored for brief periods at 4°C. Ship overnight at room temperature.